SHIZUOKA SEIKI VAL6 MAINTENANCE MANUAL Pdf Download (2024)

  1. Manuals
  2. Brands
  3. Shizuoka Seiki Manuals
  4. Heater
  5. VAL6
  6. Maintenance manual

Infrared heater

Hide thumbs Also See for VAL6:

  • Owner's manual (32 pages)
  • ,
  • Owner's manual (33 pages)
  • Bookmarks

Advertisem*nt

Quick Links

Download this manual

All manuals and user guides at all-guides.com

VAL6 Infrared Heater

KBE5S & KBE5L

(2-step)

Maintenance Manual

Table ofContents

NextPage
  • 1
  • 2
  • 3
  • 4
  • 5

Advertisem*nt

SHIZUOKA SEIKI VAL6 MAINTENANCE MANUAL Pdf Download (1)

Related Manuals for Shizuoka Seiki VAL6

  • Heater Shizuoka Seiki VAL6 Owner's Manual

    Infrared oil heater (33 pages)

  • Heater Shizuoka Seiki VAL6 Owner's Manual

    Infrared oil heater (32 pages)

  • Heater Shizuoka Seiki VAL6 KBE5S Service Manual

    (22 pages)

  • Heater Shizuoka Seiki VAL6 KBE1S Owner's Manual

    Infrared diesel heater (76 pages)

  • Heater Shizuoka Seiki VAL6 MPX5 Service Manual

    Infrared oil heater (23 pages)

  • Heater Shizuoka Seiki VAL6 MPX Owner's Manual

    Infrared oil heater (88 pages)

  • Heater Shizuoka Seiki VAL6 EPX1 Maintenance Manual

    (19 pages)

  • Heater Shizuoka Seiki VAL6 EP8JA Owner's Manual

    Infrared oil heater (20 pages)

Summary of Contents for Shizuoka Seiki VAL6

  • Page 1 All manuals and user guides at all-guides.com VAL6 Infrared Heater KBE5S & KBE5L (2-step) Maintenance Manual...
  • Page 2 All manuals and user guides at all-guides.com ■ Wiring Diagram of Burner Control ●KBE5S ●KBE5L 2-step ■ Sequence Time Chart ignition Operation Switch Igniter Solenoid Pump 5 sec. 180 sec. within 10 sec. 10 sec. (post ignition)
  • Page 3: Operation Flow Chart

    All manuals and user guides at all-guides.com PAGE# 1 Operation Flowchart KBE5S, KBE5L(2-step) MODEL: Remedy Possible Cause Put fuel into the tank Fuel is leaking ● Drain packing and/or bolt is damaged ● There is too much fuel in the tank Plug into the power supply Fuse blows out ●...
  • Page 4 All manuals and user guides at all-guides.com PAGE# 2 Operation Flowchart KBE5S, KBE5L(2-step) MODEL: Remedy Possible Cause Misfire lamp is lit ● Terminals of control device is uncoupled (for KBE5L) (for KBE5S)*1 *1 KBE5S manufacturered from 2006 to 2013(Serial# J-04 to D-05) Overvoltage lamp is lit Direct sunlight hits flame monitor ●...
  • Page 5 All manuals and user guides at all-guides.com PAGE# 3 Operation Flowchart KBE5S, KBE5L(2-step) MODEL: Remedy Possible Cause Fuel pump is idling with ● Fuel pump is inhaling remaining air in fuel line (especially brand-new heater or after refueling) ● Pump is inhaling air from the fittings of fuel line between tank and fuel pump Fuel is sprayed normally from ●...
  • Page 6 All manuals and user guides at all-guides.com PAGE# 4 Operation Flowchart KBE5S, KBE5L(2-step) MODEL: Remedy Possible Cause Combustion is stable ● Nozzle is clogged ● Fuel pump is clogged or defective Combustion level can switch into High/Low (for KBE5L 2-step only) ●...
  • Page 7 All manuals and user guides at all-guides.com PAGE# 5 Operation Flowchart KBE5S, KBE5L(2-step) MODEL: Remedy Possible Cause The unburnt component may come out under the temperature of Smell of fuel comes out combustion chamber is low right after ignition. This unburnt component causes odor.
  • Page 8 All manuals and user guides at all-guides.com VAL6 KBE5S & KBE5L Trouble Shooting Possible Cause How to check Result Remedy Fuel is leaking Drain packing and/or Remove fuel from tank Fuel leaks because of Replace a drain bolt is defective and take out a drain bolt.
  • Page 9 All manuals and user guides at all-guides.com VAL6 KBE5S & KBE5L Trouble Shooting Possible Cause How to check Result Remedy At the time of turning on operation switch If value leads ∞Ω, the Fan motor is short- Disconnect fan connector...
  • Page 10 All manuals and user guides at all-guides.com VAL6 KBE5S & KBE5L Trouble Shooting Possible Cause How to check Result Remedy Heater cannot start up (heater does not operate at all with switching on) Operation lamp is not lit (No lamp is lit) If the value shows ∞V,...
  • Page 11 All manuals and user guides at all-guides.com VAL6 KBE5S & KBE5L Trouble Shooting Possible Cause How to check Result Remedy 16 Circuit board (Burner Measure voltage at input If power source is Replace circuit control) is defective side of transformer...
  • Page 12 All manuals and user guides at all-guides.com VAL6 KBE5S & KBE5L Trouble Shooting Possible Cause How to check Result Remedy Electrode is not sparking 24 Ignition transformer Connect connection connector (CN4) or of ignition high-voltage cord is transformer loose connection...
  • Page 13 All manuals and user guides at all-guides.com VAL6 KBE5S & KBE5L Trouble Shooting Possible Cause How to check Result Remedy Fuel is not sprayed normally from the nozzle 33 Fuel line is clogged Clear the clog in fuel line 34 Fuel filter (element) is...
  • Page 14 All manuals and user guides at all-guides.com VAL6 KBE5S & KBE5L Trouble Shooting Possible Cause How to check Result Remedy 37 Fuel filter and/or Because of low Warm the fuel or nozzle is clogged by temperature, fuel mix kerosene with...
  • Page 15 All manuals and user guides at all-guides.com VAL6 KBE5S & KBE5L Trouble Shooting Possible Cause How to check Result Remedy 43 Flame monitor is Disconnect flame If the valu of resistance is Replace a flame defective monitor connector nonstandard, the flame...
  • Page 16 All manuals and user guides at all-guides.com VAL6 KBE5S & KBE5L Trouble Shooting Possible Cause How to check Result Remedy Combustion stage can switch (for KBE5L 2-step only) 51 Change-over switch Plug change-over switch If it works normally, Plug in connector...
  • Page 17 All manuals and user guides at all-guides.com VAL6 KBE5S & KBE5L Trouble Shooting Possible Cause How to check Result Remedy Heater produces BLACK smoke 56 Combustion air is Check whether a If the combustion fan Replace a insufficient combustion fan is run...
  • Page 18 All manuals and user guides at all-guides.com VAL6 KBE5S & KBE5L Trouble Shooting Possible Cause How to check Result Remedy Smell of fuel comes out 58 Combustion air is too Check whether air inlet If air inlet opening if too...
  • Page 19 All manuals and user guides at all-guides.com VAL6 KBE5S & KBE5L Trouble Shooting Possible Cause How to check Result Remedy Electrode Nozzle ±0.5mm ±0.5mm Electrode ±0.5mm Drawing...
  • Page 20 All manuals and user guides at all-guides.com How to restore the fuel flow If the heater produces a lot of black smoke, is difficult to fire or never ignites; please perform the following procedures before replacing the pump and/or nozzle. Make sure that the pump turns on (you can feel and hear the vibration).
  • Page 21 All manuals and user guides at all-guides.com Chart 1 Chart1 Standard resistance of functional parts Parts Connector No Lead Condition Resistance Remarks 0Ω Operation Switch Yellow-Yellow ∞Ω Change-over Switch High 0Ω Blue-Blue ∞Ω (KBE5L 2-step only) dark over 2MΩ Photo Cell CN11 Black-Black light...
  • Page 22 All manuals and user guides at all-guides.com Picture 1 How to measure resistance How to measure voltage Picture 1 Picture 2 Pull out a connector which you will ① ① Operate the heater measure from burner control ② Turn on the circuit tester and set AC Turn on the circuit tester and set resistor voltage range ②...
  • Page 23 All manuals and user guides at all-guides.com Inspection surge absorber (SA1) Picture 4 Take out the burner control, and point the lead head at solder part of SA1 Inspection draft tube and fan Inspection fuse① Picture 5 Picture 6 Object Serial Number : till 01Q-020000 (2003/2004 model) whirl vane draft tube In case of draft tube and fan...
  • Page 24 All manuals and user guides at all-guides.com Adjustment of air inlet for using the heater in high altitude Picture 9 If dark smoke comes out or flame protrudes from the radiation disk in using the heater in an altitude higher than 3,000 ft, you need to expand combustion air inlet opening.
  • Page 25: Inspection Of The Filter And Drainage Of Water From The Fuel Tank

    All manuals and user guides at all-guides.com Daily Inspection Inspection of the tank inlet filter Please remove the fuel cap and check if dirt/ dust sticks to the inlet filter If there are any dirt/dusts, remove the filter and wash it with fuel. Please restore the tank inlet filter, and tighten firmly the fuel cap.
  • Page 26: Inspection And Cleaning Of The Flame Monitor

    All manuals and user guides at all-guides.com Inspection and cleaning of the flame monitor Observations - When removing the flame monitor, hold it by its main assembly; do not pull out the cord. Remove the burner cover and pull out the flame monitor, and check whether or not its lens is dirty/foul.

This manual is also suitable for:

Kbe5sKbe5l

SHIZUOKA SEIKI VAL6 MAINTENANCE MANUAL Pdf Download (2024)
Top Articles
Latest Posts
Article information

Author: Kareem Mueller DO

Last Updated:

Views: 5431

Rating: 4.6 / 5 (46 voted)

Reviews: 85% of readers found this page helpful

Author information

Name: Kareem Mueller DO

Birthday: 1997-01-04

Address: Apt. 156 12935 Runolfsdottir Mission, Greenfort, MN 74384-6749

Phone: +16704982844747

Job: Corporate Administration Planner

Hobby: Mountain biking, Jewelry making, Stone skipping, Lacemaking, Knife making, Scrapbooking, Letterboxing

Introduction: My name is Kareem Mueller DO, I am a vivacious, super, thoughtful, excited, handsome, beautiful, combative person who loves writing and wants to share my knowledge and understanding with you.